PrevDoc | NextDoc |
![]() | Governor's Office of Emergency Services Hazardous Material Spill Update CONTROL#: 24-3962 NRC# 1404408 |
NOTIFY DATE/TIME: 07/11/2024 / 1348 | RECEIVED BY: OCCURENCE DATE/TIME: 07/11/2024/1130 | CITY/OP. AREA: Princeton/Colusa County COLUSA COUNTY APCD |
AGENCY: NRC | ![]() |
AGENCY: Central Valley Gas Storage | ![]() |
a. SUBSTANCE: | b. QTY: Amount | Measure | c. TYPE: | d. OTHER: | e. PIPELINE | f. VESSEL >= 300 Tons |
1.Natural Gas | Unknown | Unknown | VAPOR | No | No | |
2. | No | No | ||||
3. | No | No | ||||
Orignal Description:Per NRC Report: The caller reported a release of an unknown amount of natural gas from an underground well into the atmosphere at the incident location. The cause of the release is due to the tubing blowing out of the well during installation of the tubing. The caller believes there was a build up of pressure in the well that caused the release, and it is believed to be due to equipment failure. There is a plug in the well that is used to prevent build-up, and they believe the plug failed. Remedial Actions: Wellhead is isolated. The blowout preventer and master valve have been secured. ---INCIDENT DETAILS--- Pipeline Type: TRANSMISSION DOT Regulated: YES Pipeline Above/Below Ground: BELOW Exposed or Under Water: NO Pipeline Covered: UNKNOWN | ![]() | ![]() | ||||
![]() | ![]() | ![]() |
NAME: | AGENCY: | PHONE#: | Ext: | PAG/CELL: |
![]() | NRC | ![]() | ![]() | ![]() |
UPDATE QUANTITY Amount |
|
1. |
|
2. 35,000 |
|
3. |
|
4. |
|
![]() UPDATE KNOWN IMPACT: | ![]() |
![]() | ![]() |
![]() UPDATE CAUSE: | ![]() |
SITUATION UPDATE: | |
Per NRC 1404996: "THIS IS A 48 HOUR UPDATE TO NRC REPORT 1404408. THE CALLER REPORTED THAT THE QUANTITY RELEASED HAS BEEN DETERMINED TO BE APPROXIMATELY 35,000 STANDARD CUBIC FEET OF NATURAL GAS. THE TEMPORARY LOSS OF WELL CONTROL HAS BEEN DETERMINED TO BE DUE TO A LEAKING PACKING PLUG WHICH CAUSED PRESSURES TO RISE, CAUSING THE TUBING TO EJECT FROM THE BOP STACK. THE TUBING AND THE INFLATABLE BRIDGE PLUG HAVE BEEN REMOVED FROM THE SITE. PRESSURE WAS NOT EQUALIZED FROM BETWEEN BELOW THE BRIDGE PLUG AND THE BOP STACK, WHICH IS THE ROOT CAUSE OF THIS INCIDENT." | |
Link to Spill Report: http://w3.calema.ca.gov/Operational/MALHaz.NSF/SpillAllDocs/68464BC2EAD5316688258B570072461B?OpenDocument | |
FAX NOTIFICATION LIST: | |
AA/CUPA, DTSC, RWQCB, US EPA, USFWS, AIR RESOURCES BD, Cal GEM, SFM, Co/WP, Co/Hlth, Co/E-Hlth | |
ADMINISTERING AGENCY: | Colusa County Environmental Health |
SECONDARY AGENCY: | |
ADDITIONAL COUNTIES: | |
ADDITIONAL ADMIN. AGENCY: | |
OTHER NOTIFIED: | |
RWQCB Unit: | 5B |
Cal GEM: | Northern |
Cal OES Region: | |
![]() | ![]() |
![]() CONFIRMATION REQUEST: | ![]() |
![]() | ![]() |
![]() FAX NOTIFICATION LIST: | ![]() |
![]() ADMINISTERING AGENCY: | ![]() |
![]() ADDITIONAL ADMIN. AGENCY: | ![]() |
![]() SECONDARY AGENCY: | ![]() |
![]() ADDITIONAL COUNTIES: | ![]() |
![]() Cal GEM: | ![]() |
![]() RWQCB Unit: | ![]() |
![]() Cal OES Reg. | ![]() |